What Size Wire For A 175 Amp Residential Service

When installing a 200 amp electrical service, yous need to be sure you use the correct gauge wire. You'll need a permit to do the professional installation. Many areas still allow homeowners to obtain their permits. You'll need to cheque with your local building department to know if yous can get the permit or if you lot'll need the aid of an electrician.

Installation of 200 amp electrical service needs a #2/0 AWG copper wire or #4/0 AWG for aluminum or copper-clad wire inside a minimum of i.v inches, schedule 40 or 80 PVC conduit for underground service. However, 2 or 2.5 inches is recommended if running 3 wires in the same conduit.

Wiring 200 amp service requires an electrical permit and professional person installation by a qualified electrician in accordance with local electric codes.

Power is received from the utility service lines and flows through the outside electrical meter base of operations and into the chief electrical panel in an attached garage, basement, or interior room.

Wire Sizes for 200 Amp Service

AWG, American Wire Gauge, is the Us standard for sizing electrical wiring.

Wiring a 200 amp feeder requires either #2/0 copper wiring or #iv/0 aluminum or copper-clad wiring. Which wire is used is determined by the voltage drop and length of the wiring.

The following table reflects wiring size, length, and voltage drop:

Service or Feeder Rating Copper Wire Aluminum or
Copper-Clad Aluminum Wire
Minimum Conduit Size
100 Amps #iv AWG #2 AWG 1.25 inch
110 Amps #3 AWG #1 AWG ane.25 inch
125 Amps #2 AWG #1/0 AWG 1.25 inch
150 Amps #i AWG #ii/0 AWG 1.25 inch
175 Amps #1/0 AWG #three/0 AWG 1.five inch
200 Amps #2/0 AWG #4/0 AWG 1.5 inch
225 Amps #iii/0 AWG 250 kcmil 1.5 inch
250 Amps #4/0 AWG 300 kcmil 2 inch
300 Amps 250 kcmil 350 kcmil 2.five inch
350 Amps 350 kcmil 500 kcmil 3 inch
400 Amps 400 kcmil 600 kcmil three inch
Source: National Electrical Code

Many electrical contractors opt to use #4/0 aluminum or copper-clad wire.

For copper conductors, yous'll need a #ii/0 AWG copper wire commonly used for electric wiring because it is more heat resistant than aluminum. Copper won't rust and is resistant to oxidation.

For aluminum or copper-clad aluminum wiring, yous'll need #4/0 AWG aluminum wiring. Aluminum wiring requires a larger diameter wire considering it has a lower electrical conductivity than copper. Aluminum wiring requires an antioxidant coating at the connection terminals to resist corrosion. Copper-clad aluminum doesn't crave an antioxidant blanket at the connection terminals.

Aluminum wirings appeal widespread because it costs less, is lightweight, and is more than flexible than copper, even though copper is considered a better conductor.

Why Copper Wiring is Preferred over Aluminum

Electricians and homeowners alike prefer copper wiring, peculiarly for co-operative circuits. Copper wiring has many benefits, including:

  • Electrical conductivity: Copper wire is a highly conductive metal, second only to silver. Copper can handle a higher electric load, then you tin can use a smaller estimate wire. In fact, copper wire is nigh half the diameter of aluminum wire for the aforementioned electrical conductivity.
  • Rut Resistant: Copper wire conductive properties make the wire more heat resistant than aluminum wire. Copper wire does not expand and contract like aluminum which ways the wire connections remain tight on lugs.
  • Corrosion Resistant: Copper is resistant to corrosion. Patina is a light-green-tarnish that changes the outer colour of copper. Patina forms by oxidation, all the same, do not affect the conductivity.
  • Malleability: Considering copper is highly conductive, the wire strands are thinner, making the wire more malleable without the risk of breaking.
  • Distance: Copper conductors tin exist used over longer distances due to its highly conductive backdrop and heat resistance.

Pros of Aluminum or Copper-Clad Aluminum Wire

We just discussed why copper is preferred; however, copper-clad and aluminum wire sizes are more pop on service entry wire for several reasons, including:

  • Budget-Friendly: Aluminum wire is preferred due to its lower toll. Aluminum conductors are cheaper to produce compared to copper conductors. Aluminum copper-clad is better just does cost more than aluminum wiring. Aluminum costs much less than copper-clad and copper wires.
  • Faster Installation: Aluminum is lighter than copper and very malleable for its larger wire judge. Electricians find is piece of cake to work because is lightweight and feeds well through the electrical conduit which makes for faster installation and lowers material and labor costs.

Aluminum wiring expands and contracts with heat which causes the wire connection to loosen over time, raising the take chances of an electrical fire. Aluminum service wiring is a grouping of smaller solid aluminum strands rather than one solid wire, making the aluminum wire condom to utilise in residential homes.

The Length Your Service Wire Runs Matters

When computing wire size, yous need to know how far the service archway wires volition run from the electrical meter base of operations to the electrical console. The maximum voltage drop (we will talk over shortly) immune is 3%. The distance your service entry wire needs to travel will decide whether you use aluminum or copper wire and estimate necessary.

Service Wire Size Maximum Distance
Copper #2/0 Wire 50 feet
Copper #3/0 Wire 100 feet
Copper #4/0 Wire 150 feet
Aluminum #4/0 Wire 50 feet
Aluminum 300 kcmil 100 anxiety
Distances may vary by location. Cheque with your local building department for requirements.

You lot tin can use aluminum and copper for a 200 amp service entry wire. However, the aluminum gauge will be college due to its reduced conductivity and heat resistance properties. You can use copper wire over a longer distance.

What is Voltage Drop?

Voltage drop is the loss of voltage that occurs over the wire due to natural resistance. The longer a wire runs, the more voltage loss that occurs. The size wire gauge has to increment to start the voltage driblet.

The voltage at the circuit breaker should exist 120 volts. Using a voltage meter, accept a reading at the appliance or the farthest device. Ideally, you should not take a voltage drop higher than 3%. For a 120-volt electrical excursion, the voltage driblet should be no less than 117 volts. Likewise, on 233 volts on a 240-volt electrical excursion.

How Many Wires You lot Need for 200 amp Service

The blazon of wire you need will vary depending on your electric system. The run from the meter base of operations to the primary disconnect box or primary panel is iii-wire, consisting of ii hot wires and i neutral wire. The neural and ground bars have electrical bonding connecting the confined.

The feeder run from the chief electrical panel to the interior distribution console (subpanel) is 4-wire, consisting of two hot wires, one neutral wire, and 1 ground wire. You lot don't bail the neutral and ground bars inside subpanels.

What Size Conduit You Demand for 200 Amp Service

An electrical panel has knockouts for connecting electrical feeder conduit. You can employ either a ii-inch or 2.5-inch conduit based on the fill space you intend to occupy inside the conduit. If 3 or more than wires are within the conduit, the maximum fill space of xl%.

In Chapter nine, Table 5A of the 2017 NEC, a #4/0 Aluminum stranded conductor takes upwardly 176.3mmtwo of fill space. If you multiply 176.3mmii by four gives you a full of 705.2mmii of make full infinite used by the entire feeder.

According to Affiliate 9, Tabular array 4 of the 2017 NEC, a ii″, Schedule 80 PVC conduit has 742mm2 usable fill.

So, a 2″ conduit will suffice, or you can upsize to two.5″ if you wish for ease of pulling. Continue in mind that the expanse of the wires must be less than forty% of the internal space of the pipe when three or more wires are present.

What Size Ground Wire for 200 Amp Service

The NEC is the electric code used in the United States. The minimum size for a grounding wire for 200 amp is #4 AWG copper or #2 AWG aluminum, according to Article 250 of the 2020 NEC.

The size of the primary conductor may demand to increase for a variety of reasons, including the length of the run, available fault current, or any number of reasons. The NEC is a prophylactic guide. Local municipalities set and adopt code guidelines. Call a local electrician or your city for specific guidelines.

GROUNDING ELECTRODE Conductor SIZING (Tabular array 250.66)

Size of Primary Console Copper Conductors Aluminum or Copper-Clad Aluminum
125 Amps #8 AWG #6 AWG
150 Amps #6 AWG #4 AWG
200 Amps #4 AWG #2 AWG

What Size Ground Rod for 200 Amp Service

A ground rod needs to be at least 5/eight″ (0.625) in diameter and at least 8 to 10 feet long with a clamp and the appropriate ground wire. The ground rod needs to be driven viii feet deep into the footing and cutting back close to the basis. The wire and clamp are secured tightly to the elevation of the ground rod.

Where there is a lot of electricity in the ground, a thicker #3 size wire may be required. Two ground rods are necessary for regions where soil electrical resistance is high considering of new code requirements.

Use the correct blazon of grounding rod. Piping or rebar tin can too be used for grounding. The grounding rod must exist galvanized steel and should exist at least eight feet long.

How Many Footing Rods for 200 Amp Service

A ground rod that does not meet the NEC'due south 25 OHMS or less requirement necessitates using a second basis rod, with the ground rods being at to the lowest degree 6′ autonomously.

Y'all install a footing rod for a system, and the first ground rod has a resistance of 25 ohms or more than. According to the NEC, you must install a 2nd grounding rod. On the other hand, many contractors do not take footing resistance into account. They anticipate driving two ground rods to satisfy 250.56'southward standards regardless of actual ground resistance. As a outcome, two ground rod connections are typical merely aren't always necessary.

The NEC article 250.53(B) requires you to space grounding rods at least half-dozen anxiety apart connecting by a grounding wire. Yet, this spacing is a minimum. When using the typical 8-foot or 10-foot ground rod, you get the all-time results past spacing them at least 16 or 20 feet autonomously, much farther than the minimum vi-pes spacing.

Check Local Electric Codes & Permit Requirements

Electrical codes are ready by the National Electrical Code (NEC) just can vary by location. Using a qualified electrician ensures your 200 amp electric service meets local codes and let requirements.

The 200 amp size wire referred to in this article is from the NEC code and may vary from your local building lawmaking. Your local code will adopt or alter the NEC codes to fit their requirements.

Before the utility service can connect power to the house, you'll need a Certificate of Occupancy (CO). The let allows for a final inspection to connect the electric service. The CO is issued later on the electric piece of work has passed the building inspection.

200 Amp Electrical Service Installation Costs

Information technology'southward well-nigh impossible to accurately toll the cost of installing a 200 amp entry service in a house. We need to consider numerous factors, like location, the amount of piece of work required, and textile costs in your area. Installing a 200 amp electrical service typically includes installing a 200 amp service wire, conduit, meter base, and a 200 amp electric panel.

Based on HomeAdvisor.com, the national average cost of a complete 200 amp electric installation costs $ane,900 to $7,250, with average costs of $4,650, includes the following:

  • 200 Amp Service Panel: Boilerplate price ranges from $750 to $2000, with a median cost of $1375.
  • 200 Amp Meter Base: Average price ranges from $150 to $400, with a median price of $275.
  • 200 Amp Service Wire: Average cost ranges from $m to $5,000, with a median cost of $three,000.

According to MidPenn Electrical, a leading electrical contractor in Pennsylvania, "a new 200 amp service can price anywhere from $iv,200 to $5,000". Therefore, the HomeAdvisor cost averages seem to be reasonably accurate.

Determination

Installing 200 amp wire is not a DIY project for homeowners. Wiring a 200 amp panel is a large project that requires the services of a qualified and certified electrician. You may require a allow to install a 200 amp service. The electric service will demand to exist asunder entirely in existing homes to install the 200 amp service.

Also, run into our guide, Wire Size for 100 Amp Electric Service.